Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

Circulating Pump On My Boiler Keeps Running Please Help

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Circulating Pump On My Boiler Keeps Running Please Help
  • Supply Capacity : 10 units/month :Circulating Pump On My Boiler Keeps Running Please Help
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • circulator pump - DoItYourself.com Community Forums

    Apr 06, 2007 · Boilers - Home Heating Steam and Hot Water Systems - circulator pump - My circulator pump keeps running for more than an 1 hour and it's not stopping. Doesn't it suppose to stop at certain time? The boiler runs fine as far as I know. I have the thermostat set up at 70 degrees. I bleed the radiator I thought it mightGet Price

  • turning on and off the circulating pump with boiler

    Jan 04, 2010 · 3. The boiler turns off and the pump keeps operating for e.g. 15 more minutes. By this time the water must have cooled a lot so the pump can turn off. 4. There could be a heat sensor in the pump and if the water temperature is below a given value then the pump could turn itself off. So my question is: are there circulating pumps that have any Get Price

  • Why does my boiler say pump overrun?

    Click to see full answer Herein, why does my boiler pump keep running? Your boiler has "pump overrun" so the pump is connected directly to the boiler.The pump should run for a few minutes after the call for heat has ended. If the pump runs continuously when the boiler is off the overrun control is faulty. You will need a Gas Safe qualified engineer to repair the boiler.Get Price

  • Why does my boiler say pump overrun?

    Click to see full answer Furthermore, why does my boiler pump keep running? Your boiler has "pump overrun" so the pump is connected directly to the boiler.The pump should run for a few minutes after the call for heat has ended. If the pump runs continuously when the boiler is off the overrun control is faulty. You will need a Gas Safe qualified engineer to repair the boiler.Get Price

  • Boiler Exploded in Pakistan

    Oct 21, 2021 · Earlier, on December 22 last year, a boiler exploded in Karachi as well. Here 8 people were killed, while 15 people were injured due to the explosion in the boiler of the ice factory. According to local reports, the blast was so deadly that the factory building itself collapsed (Pakistan Boiler Explosion Incidents).Get Price

  • Rotation Tester and AC Detector for Circulating Pumps etc

    I bought this to test the central heating pump in my boiler because I suspected it was defective. The tester didn't come with particularly helpful instructions, but if held in the position shown in the 1st picture, the indicator dial rotated, so I assumed the pump was running. Upon further investigation, the pump did prove to be defective.Get Price

  • Constant Circulation - Bad? | Hearth.com Forums Home

    Nov 20, 2020 · My boiler is running into a plenum in my forced air system in the house and also through a sidearm heater on my hot water tank. It couldn't be much simpler, hot water out the top through a temperature controller to keep the water above 140 in the boiler before its released to the rest of the system, into the sidearm and then through the plenum Get Price

  • Two labourers killed in Lahore factory boiler explosion

    LAHORE: Two laborers were killed as the roof of a factory collapsed after a boiler explosion at Lahore's Raiwind Road, ARY News reported. A boiler exploded inside the factory due to …Get Price

  • Grundfos Circulating Pump Troubleshooting - JustAnswer

    Nov 04, 2010 · How do I know if the circulating pump is bad on my boiler?It is a Grundfos UPKefidF. Already Tried: The pilot lights, The flame sensor senses the flame and turns on the burner. It starts to heat up and then you hear the water making popping sounds and then jerking sounds form the water inside the place where it gets heated up.Get Price

  • Glowworm circulating pump keeps running | DIYnot Forums

    Sep 03, 2019 · I have a Glowworm Complheat 80 boiler in which the circulating pump keeps running even whan the central heating and hot water heating are turned off! It seems to run indefinately and can only be stopped when I turn off power. Turning on power starts the pump again. This is a pressurised, sealed system. Any ideas greatly appreciated. Thanks.Get Price

  • Circulating Pump On My Boiler Keeps Running. Please Help!

    Fix Heating Zone Circulator Pump that runs constantly when Get Price

  • Raypak – Technical

    Consider two copper finned tube boilers, both rated at 199,000 BTUH input, both with 1/7 HP circulating pumps, both connected to 80-gallon storage tanks. The only difference between the two systems is that Boiler A shuts down the pump when in standby mode while Boiler B pumps away continuously.Get Price

  • Factory boiler explosion kills two in Lahore | The Nation

    Oct 21, 2021 · Factory boiler explosion kills two in Lahore. The Nation | Oct 21, 2021. At least two laborers died as a boiler of beverages producing factory located at Lahore's Multan Road exploded on Thursday. As per details, the fire engulfed the factory building after its boiler exploded. The factory and the nearby buildings have been badly affected due Get Price

  • How does the circulator on a boiler work? | Shop Your Way

    Apr 26, 2007 · Systems that use an aquastat to control the pump usually do not have the pump come on until the boiler water temperature is 110F to 140F. When the boiler shuts off, some pumps shut off immediately. This leaves heat in the heat exchanger that finds its way up the chimney. It's more energy-efficient to keep the pump running until the heat Get Price

  • Boiler Circulator Pump Always Running | Terry Love

    Chris it's possible that the circulator relay on your boiler's aquastat or primary control (or circulator relay if you have multiple circulators) is stuck "on" and needs repair or replacement. Meanwhile just flip off power to the boiler - that should turn off the circulator. If it doesn't then look for an additional electrical switch.Get Price

  • Central heating boiler pump running continuously

    Sep 11, 2010 · The boiler also sets the pump going ocassionally when the boiler is not on. The live feed into the pump does originate from inside the boiler casing. I took the panel off the pump and found inside a terminal block which held the earth, neutral and live wires of the feed cable from the boiler.Get Price

  • Central Heating Circulating Pump: Troubleshooting | Living

    Boiler Circulating Pump Hot To Touch? (Possible Causes Get Price

  • Why does my boiler say pump overrun?

    Click to see full answer Furthermore, why does my boiler pump keep running? Your boiler has "pump overrun" so the pump is connected directly to the boiler.The pump should run for a few minutes after the call for heat has ended. If the pump runs continuously when the boiler is off the overrun control is faulty. You will need a Gas Safe qualified engineer to repair the boiler.Get Price

  • Two dead as factory boiler explodes in Lahore

    Nov 13, 2016 · LAHORE (92 News) – At least two people were killed as boiler of a factory exploded in Raiwind area of Lahore on Sunday. According to details, the explosion happened due to gas leakage. Two operators of the factory died in the explosion. The police and rescue teams reached the scene and started rescue operation.Get Price

  • How to Stop an Continuously Running Circulator Pump

    Nov 30, 2011 · Many of my hydronic heating designs include the use of a full time circulator but one of the zones should be open. Without a call for heat, the main boiler relay should not call the pump on. It is possible that the technician caused the problem.Get Price

  • Circulation pump continuously running | DIYnot Forums

    Sep 03, 2019 · Location: West Midlands. Country: My circulation pump is continuously running. The HW and CH is otherwise working ie coming on and off as it should, but the pump stays on, and it never used to do this. The boiler is not staying on with the pump. It is operating as it should do when called for by HW and CH. I have had problems with the actuators Get Price

  • Hot water baseboard, no heat, boiler, circulator on | DIY

    Jan 24, 2013 · Hey, need big help with this, it's7 degrees, with no heat but a wood stove. I just turned my boiler on last night, it heated up, woke up to no heat. Temps/pressure were normal on boiler, circulator pump was very hot to the touch. I replaced the circulator, still no heat, and it was very hot also after running for 10 minutes or so.Get Price

  • Why does my boiler say pump overrun?

    Click to see full answer Furthermore, why does my boiler pump keep running? Your boiler has "pump overrun" so the pump is connected directly to the boiler.The pump should run for a few minutes after the call for heat has ended. If the pump runs continuously when the boiler is off the overrun control is faulty. You will need a Gas Safe qualified engineer to repair the boiler.Get Price

  • Circulator Pump runs 24/7 - DoItYourself.com Community Forums

    Nov 20, 2011 · Circulator Pump runs 24/7. Hi everyone, First time poster, but I've found the info on this site to be very helpful - thank you. I have a gas-fired Weil-McLain CGa boiler with four zones, each with a White-Rodgers 1361 zone valve and each with its own thermostat. I replaced my Taco circulator pump yesterday and I'm now noticing that the wiring Get Price

  • Why does my boiler say pump overrun?

    Click to see full answer Herein, why does my boiler pump keep running? Your boiler has "pump overrun" so the pump is connected directly to the boiler.The pump should run for a few minutes after the call for heat has ended. If the pump runs continuously when the boiler is off the overrun control is faulty. You will need a Gas Safe qualified engineer to repair the boiler.Get Price

  • Why does my boiler say pump overrun?

    Click to see full answer Herein, why does my boiler pump keep running? Your boiler has "pump overrun" so the pump is connected directly to the boiler.The pump should run for a few minutes after the call for heat has ended. If the pump runs continuously when the boiler is off the overrun control is faulty. You will need a Gas Safe qualified engineer to repair the boiler.Get Price

  • wiring - How can I switch a circulation pump between

    Feb 27, 2021 · While the boiler and pump are on separate feeds coming out of the control unit, they are switched simultaneously so the pump operates only when the boiler is fired. Twice this winter, a branch of the water circulation route froze. Each incident resulted in a $480 service call to thaw the line. This is unprecedented in my home. After the second Get Price

  • Circulation pump permanently on | Electricians Forums

    Apr 10, 2017 · Can anyone help, I have looked at a central heating pump for my brother in law (who is a plumber!? it is an HRM oil fired boiler, the problem is that the circulation pump is permanently on, there is underfloor heating with the system, the wiring is shocking and I will probably have to re wire everything but just looking at a quick fix prior to pulling it all out and …Get Price

  • Central Heating - Over running pump - Advice needed

    My boiler has a separate pump wired in parallel, so both are switched on/off at the same time by the timer / thermostat. so the boiler stays off and …Get Price

  • Econoburn 100 Circulating loop pump | Hearth.com Forums Home

    Jan 02, 2017 · The Econoburn manual suggests a two pump set up. The near boiler pump runs until the boiler loop hits 150. At 150 it shuts off and the pump to storage (or load) comes on. I don't use the two pumps on my system but I don't remember reading anything about a differential setting. I thought it was one off, one on, at 150 degrees.Get Price

Discount
7X24 Online